Strona 1 - User’s Guide

User’s GuideXR200User’s GuideXR200

Strona 2

66General Arming OperationYour system has been programmed to operate in one of threemodes: Area Arming, All/Perimeter, or Home/Away.• Area Arming - Yo

Strona 3 - Table of Contents

77Arming and DisarmingArea System ArmingArea Assignment: Your security system has been set up intoseparate areas. The number of areas and their names

Strona 4 - Emergency Evacuation Plans

88Area System DisarmingDisarming: While the system is armed, you can only enter thepremises through an entry/exit delay door without causing an alarm.

Strona 5 - Introduction

99All/Perimeter System ArmingArea Assignment: Your security system is divided into two separateareas. Motion detectors, inside doors, and other interi

Strona 6 - The Security Command Keypad

1010All/Perimeter System DisarmingDisarming: While the system is armed, you can only enter thepremises through an entry/exit delay door without causin

Strona 7 - Special Wireless Displays

1111Home/Away System ArmingArea Assignment: Your security system is divided into two or threeseparate areas. Motion detectors, inside doors, and other

Strona 8

1212Home/Away System DisarmingDisarming: While the system is armed, you can only enter thepremises through an entry/exit delay door without causing an

Strona 9

1313User MenuUser MenuSecurity Command User MenuMany of the features of your system have been put into a User Menuthat you can access from any Securit

Strona 10 - General Arming Operation

1414Alarm SilenceUser Code Level: 2 and above.Function: Silences the alarm bell or siren during an alarm.Alarm Silence allows you to turn off the ala

Strona 11 - Area System Arming

1515Door AccessUser Code Level: 1 and 2 - During schedules only. 3 to 9 - Anytime.Function: Operates an electric door strike from the keypad.Door Acce

Strona 12 - Area System Disarming

Copyright© 1995 - 1997 Digital Monitoring Products, Inc.Information furnished by DMP is believed to be accurate and reliable.This information is subje

Strona 13 - Perimeter

1616Outputs On OffUser Code Level: 5 and above.Function: Allows you to turn the system relay outputs on and off.This function is used to individually

Strona 14

1717Zone Status continued8. At the ZONE NO: - prompt, enter the zone number you want tocheck and press COMMAND. The zone number and name isdisplayed f

Strona 15 - Home/Away System Arming

1818User MenuZone MonitorUser Code Level: 4 and above.Function: Allows the system to monitor selected disarmed zones(doors, windows, or motion detec

Strona 16 - Home/Away System Disarming

1919System StatusUser Code Level: 1 and 2 - During schedules only. 3 to 9 - Anytime.Function: Displays the current condition of internal system hardwa

Strona 17 - User Menu

2020The following table lists system functions users are allowed toaccess based on the authority level assigned to their codes.User Code Authority Lev

Strona 18 - Sensor Reset

2121User Codes continuedProgramming Custom User CodesIn addition to the preset authority levels, you can also create customauthority levels by selecti

Strona 19 - Armed Areas Display

2222User Codes continuedAmbush CodesYour system may be programmed to allow user number 1 to be anAmbush code. This Ambush code functions identically t

Strona 20 - Zone Status

2323SchedulesUser Code Level: 7 and above.Function: The Schedules function allows you to enter into thesystem the times at which you normally turn yo

Strona 21 - Bypass Zones

2424User MenuSchedules continuedArea SchedulesYour system may be programmed for Area schedules that allowsyou to set a separate schedule for each area

Strona 22 - Zone Monitor

2525User MenuRelay Output SchedulesThe Schedules function allows you to set up to 50 different scheduledtimes for relays connected to your system to t

Strona 23 - System Test

About your systemEmergency Evacuation Plans ...iiAbout Your Security System...

Strona 24 - User Codes

2626User MenuArea # __ , orInt or PerimPRM - PRITMP - SECOpeningClosing : _ M : _ M : _ M : _ M :

Strona 25 - Areas systems only

2727Setting the Date and TimeUser Code Level: 8 and above.Function: Allows you to change the current date and time displayedon the Security Command k

Strona 26

2828Display EventsUser Code Level: 1 and 2 - During schedules only. 3 to 9 - Anytime.Function: Allows you to review up to 200 past system events.There

Strona 27 - Schedules

2929About the Display Events SectionThis section of the user’s guide shows the User's Guide DisplayEvents items for both 16-character (single lin

Strona 28 - Schedules continued

3030User Code Change Event DisplaysThis displays any addition, deletion, or change to a user code.16-Character Display Description12 ADD 19 1017 U

Strona 29 - Relay Output Schedules

3131Door Access Event DisplaysThis displays the keypad address where a *Door Access occurredand the user number of the person granted access.16-Charac

Strona 30

3232Zone Bypass Event DisplaysThis displays the bypassing of system zones.16-Character Display Description26 BYPS 12 1017 Zone 26 bypassed by user

Strona 31 - Setting the Date and Time

3333System SetupWe've provided this System Setup section to allow you to track thecurrent and future status of the programmable options on yourSe

Strona 32 - Display Events

3434Area names and numbersIf you have an area system where your system is divided into up toeight separate areas, each area can have a custom name ord

Strona 33

3535LEVEL CUSTOMARM/DIS YESARM/DIS NOCOMMAND= press this SELECT key.)(Press the COMMAND key to display the next menu option.Use the

Strona 34

Emergency Evacuation PlansThe National Fire Protection Association recommends that youestablish an emergency evacuation plan to safeguard lives in the

Strona 35 - Door Access Event Displays

3636Suggestion: Photocopy this page before using.User User Name Level Areas of access1 2 3 4 5 6 7 81 2 3 4 5 6 7 81 2 3 4 5 6 7

Strona 36 - SERVICE REQUEST?

3737System SetupFrequently asked questionsThis section of the user's guide attempts to answer questions youmight have regarding the operation of

Strona 37 - Security Command keypads

3838Zone Status BrowserStart HereAppendixZone Status BrowserStart HereAppendixZONE STATUS?ARM BYPS ALR NBRZONE NO: –SELECT ZONE . . .COMMANDAccess the

Strona 38

3939BYPASS ZONES?ZONE: – RST BYPSELECT ZONE . . .COMMANDAccess the User Menu. PressCOMMAND until BYPASS ZONESappears. Press any SELECT key.Press

Strona 39

4040Zone Monitor BrowserAppendixSELECT ZONE . . .COMMANDAccess the User Menu. PressCOMMAND until ZONE MONITOR?displays. Press any SELECT key.Press the

Strona 40 - Suggestion

4141Add User Codes BrowserAppendixStart HereUSER CODES?ADD DEL CHGUSER NUMBER: –1243USER NUMBER: 012COMMANDCODE NO: 1 2 3 4Access the User Menu. Pre

Strona 41 - Frequently asked questions

4242Delete User Codes BrowserAppendixUSER CODES?ADD DEL CHGUSER NUMBER: –1243MIKE JONESCOMMANDAccess the User Menu. Pressthe COMMAND key until USERC

Strona 42 - Zone Status Browser

4343AppendixChange User Codes BrowserStart HereUSER CODES?ADD DEL CHGUSER NUMBER: –1243MIKE JONESCOMMANDAccess the User Menu. PressCOMMAND until USE

Strona 43 - Bypass Zones Browser

4444AppendixEntering Custom Names–Once you've cleared the defaultname, the display shows just adash on the left side.To enter a custom name intot

Strona 44 - Zone Monitor Browser

4545The relay activatesmomentarily duringwhich you must openthe door.Once you open the door,you have 30 seconds toexit and close the doorbefore the zo

Strona 45 - Add User Codes Browser

11About Your Security SystemThe Security Command system has been designed with your safetyand comfort in mind. It uses the latest in computer based t

Strona 46 - Delete User Codes Browser

4646ARMING AND DISARMING AN ALL/PERIMETER SYSTEMPress Command. The keypad displays PERIM ALL (when arming) or DISARM?.Press the Select key under the

Strona 47 - Change User Codes Browser

4747Pager Direct™Security Command Alphanumeric PagingArea NamesSecurity Command Numeric PagingArea NamesPager Direct™ User's GuidePager Direct us

Strona 48 - Entering Custom Names

4848Account NumberWhenever the system sends a message to your pager, it will always send the accountnumber first to identify itself. After the account

Strona 49 - Easy Entry™ User's Guide

4949FA100 User's GuideThese instructions guide you through the operation of your system using the FA100 Wireless Command Transmitter. The FA100 o

Strona 50 - Appendix

5050Alarm display 3Ambush codes 22Area Schedules 24Armed Message 6ArmingAll/Perimeter mode 9, 46Area mode 7, 45Home/Away mode 11, 46Instant mode 9, 11

Strona 51 - Cut along dotted lines

LT-0287 (11/97)LT-0287 (11/97)

Strona 52 - Numeric Pager Display

22IntroductionData Entry keysThese keys allow you to enter your user code when arming ordisarming or enter other information into the system.The ARROW

Strona 53 - FA113 User's Guide

33Special Security Command DisplaysAs you use your system, you’ll occasionally see a keypad displaythat asks you to enter a code or that describes a c

Strona 54

44Special Security Command TonesYour keypad also contains a small speaker that allows it to alert youto events as they occur on your system. Below are

Strona 55 - LT-0287 (11/97)

55Understanding Security System TermsEntry or Exit zoneAlmost all systems have one or more doors through which you canenter or exit the premises. Thes

Komentarze do niniejszej Instrukcji