35445 Migration Microsoft Excel Report configuration does not retain the definition
filename after the upgrade from R400 to R500
Reenter the Microsoft Excel report
filename after upgrade
36810 Migration Alarm duration reports lose their event type when a SCAN 3000
R620.3 is migrated to ProcessLogix R500
Reconfigure alarm/event and alarm
duration reports after upgrade.
35715 Operator Security Operator idle timeout supersedes Station idle timeout only on Static
stations
35053 Point Browser Browser does not auto update when new point downloaded from
Quick Builder
Change the selection under "Show
Points from Area" or even reselect
the current selection
36843 Point Control
Scheduler
A schedule entry is not rejected immediately when entered with a
date/time set in the past
40602 Reports The alarm and event report outputs errors to the log when operator
scope of responsibility is applied
34266 Scripting Periodic script selection resets to the top one when a script is
committed
34482
1-854J0
Scripting Script editor cursor disappears when Quick Builder help is open and
text is selected
Close help before going back to
script editor
34595 Scripting When the script debugger is attached to scripts the script should
not time out
Either set the timeout for the script
to zero using Script.Timeout = 0 or
set the timeout for the engine to
zero.
35457 TDC CL Compiler Duplicate TDC CL Acronyms are allocated when a CL program is
recompiled
Ensure that identifiers are
restricted to 10 characters.
Table 4 Known Station Problems in R500.1 SP1
ISR Subsystem Description Workaround
Table 5 Known Client Problems in R500.1 SP1
ISR Product Description
23200 Station Can't select an alphanumeric by tabbing to it and hitting backspace on HMIWeb displays.
23498 Station Combobox does not fire onkeydown, onkeyup, or onkeypress events on HMIWeb displays.
24951 Station HMIWeb pages don't work within HTML frames
25917 Station Alphanumeric no longer indicates write enabled/disabled state visually
27026 Station Alphanumeric does not give focus indication under certain circumstances
28094 Station Alphanumerics display red dashes if displaying gated history on HMIWeb displays.
28976 Station Selection rectangle remains, after alarm ack on DSP alarm line
29439 Station Backspace key does not toggle the state of checkboxes on HMIWeb displays.
29810 Station No user feedback is given when you enter an incorrect display path or server name in the
connection properties display path and then try to browse.
30268 Station Starting Knowledge Builder, from the Help menu, works but it starts behind Station